Charlotte, NC Mon–Fri 9am – 4:30pm

Tenant Signs: A Storefront Submittal Guide

Tenant Signs: A Storefront Submittal Guide

Tenant signs are the storefront identification a shopping center, office building, or mixed-use landlord allows one occupant to install. Most projects stall because the tenant designs the logo first and reads the criteria second. The faster path is to treat the landlord's sign criteria as the design brief, then build one approval packet around the allowed sign band, letter height, illumination, and drawing set.

Get a free quote

Carolina Signs and Wonders builds these projects in Charlotte and installs across North Carolina and South Carolina. Design, permitting drawings, fabrication, and installation stay with one team, so the packet the landlord reviews is the packet the city sees.

What should a tenant sign submittal prove?

A tenant sign submittal proves that one storefront sign fits the space the lease already granted. It is not a request to rewrite the property's sign program, and it is not a parking or directory sign. Those are separate products. This packet is about the occupant's own identification on the facade.

Landlords usually want the same core proof, even when the wording differs:

  • The business name and logo, with no phone number, website, or product list on the fascia.
  • A scaled storefront elevation showing where the sign sits on the sign band.
  • Letter height, overall length, and sign area compared with the written limit.
  • Illumination method, colors, returns, and the raceway or mount finish.
  • A note that electrical parts are concealed and serviceable.

One published shopping-center criteria set asks for final shop drawings within 10 days of lease execution, including color, materials, size, installation, and a scaled elevation. If several signs are proposed, it also asks for a key plan. Written landlord approval comes before the permit application, and a copy of the permit goes back to the landlord before installation. The Vestar sign approval criteria is a useful example of that sequence, not a substitute for the exhibit in your own lease.

Answer in brief: the submittal proves fit, not ambition. If the drawing cannot show the sign inside the allowed band, the logo is not ready to fabricate.

Which facts should you pull from the lease before design?

Open the lease exhibit before anyone opens a design file. The criteria, not the brand book, decides what can be built. When the landlord's rule and the city rule disagree, the stricter one governs. That is a common sentence in shopping-center criteria, and it saves a redesign.

Collect these items in one note:

  • Allowed sign count. In-line spaces often get one sign on the storefront elevation. End caps and outparcels may get more, but only if the criteria says so.
  • Placement. Many criteria center the sign on the tenant's frontage and center it vertically in the sign band. Rear signs are often landlord discretion, not a right.
  • Size method. A common pair of limits is 75 percent of the sign band and up to 2 square feet of sign face per linear foot of storefront. Letter height often steps up with frontage, for example shorter letters on a frontage under 30 feet.
  • Allowed and banned types. Internally illuminated channel letters, halo letters, and a contour cabinet are often allowed. Exposed neon, flashing or moving signs, painted-on lettering, and illuminated awnings are often banned.
  • Shared signs. A panel on the shopping center pylon sign is a separate approval. Location on that sign is usually the landlord's call, not the tenant's.

Do not treat a sample percentage as your city's rule. Confirm the local sign ordinance too. The landlord can be stricter than the city. The city cannot be ignored because the landlord said yes.

Carolina Signs and Wonders reads this exhibit during discovery, then walks the space. A criteria line about "centered in the sign band" only means something once someone measures the band, the columns, and the door.

How do you confirm the sign band and letter size?

Measure the premises, not the whole building. The tenant's frontage is the width of that lease space. The sign band is the horizontal zone the landlord designated above the storefront, often between a canopy and the parapet or between two architectural lines.

Use a simple field check:

  1. Photograph the full elevation straight on, then each end of the band, in daylight.
  2. Measure the linear frontage and the clear height and depth of the sign band.
  3. Note the facade material: brick, EIFS, metal panel, or glass. Weight and fasteners depend on it.
  4. Sketch existing penetrations, joints, and any old sign holes the new sign must cover or avoid.
  5. Mark the electrical source if the sign will be illuminated, including where a disconnect can hide.

Then test the logo against the limits you already copied from the criteria. If letters at the brand's preferred height exceed 75 percent of the band, or the area exceeds the square-foot-per-foot rule, shrink the logo before the first landlord review. A sign that looks correct in a deck and fails the elevation is the usual reason a submittal comes back.

Our installers and project managers do this measurement as part of the site walk. The Charlotte shop then fabricates to those field dimensions, which matters when a national brand standard meets a local band that is shorter than the brand template assumes.

Gloved hands measuring the clear height of a blank storefront sign band above the glass

Which sign types usually survive landlord review?

Criteria lists are narrower than a full sign catalog. For a typical retail inline space, the conversation is usually channel letters on a raceway, halo letters, or a shallow cabinet, not a monument and not a pylon.

OptionWhat the landlord is judgingWhen it usually fits
Face-lit channel letters on a racewayRaceway painted to the fascia, letters centered, and transformers hidden.A common default when the criteria requires a matching raceway.
Halo-lit reverse channel lettersFace color, return depth, and whether the halo stays inside the band.Facades where the criteria wants light without a bright letter face.
Contour cabinetShape, depth, and whether it reads as one sign rather than a box.When a cabinet is allowed and the logo does not work as separate letters.
Non-illuminated dimensional lettersWhether non-lit signs are permitted at all.Only if the criteria allows them. Some centers ban non-lit fascia signs.

The raceway versus direct-mount choice is often already made by the criteria. If the document says the sign mounts on a raceway matched to the fascia, do not submit a direct-mount detail to "clean up" the look. That is a different approval. The channel-letter product page covers construction. This submittal only needs the method the landlord already allowed.

Skip anything the criteria bans in plain language. Exposed neon, open-face letters with visible tubing, flashing or rotating elements, and letters painted on the fascia get rejected even when the size is correct.

What should you fix before the landlord reviews it?

Most rejections are small and expensive. The logo is right and the size is wrong, or the size is right and the raceway color is missing. Catch those on your own sheet before the property manager does.

Check the packet against this list:

  • The business name matches the lease. A shortened brand name needs written landlord acceptance.
  • No tagline, hours, phone number, or product art sits on the fascia.
  • Letter height and overall length are labeled on the elevation, not only in a caption.
  • The sign area is calculated and set next to the criteria cap.
  • The raceway or return color is called out as a match to the existing fascia, not left open.
  • Wiring, transformers, and labels are noted as concealed, with a service path.
  • The vendor's insurance is ready if the criteria asks for it before site work.

If a national brand template is wider than the local band, change the template. Do not ask the landlord for a variance as the first move. Variances slow the opening and often fail because the center already gave every other tenant the same limit.

We mark these items in the first drawing pass at the Charlotte shop. That keeps the landlord review on the logo and placement, which is the decision they actually need to make.

A fabricator reviewing storefront elevation drawings beside metal letter returns on a shop bench

What belongs in the drawing set?

Build one PDF the landlord can approve and the permit office can reuse. A render without dimensions is not a shop drawing.

Include:

  • A scaled elevation of the tenant frontage with the sign centered in the band.
  • Letter height, overall length, returns, and sign area, next to the criteria limit.
  • Face, return, and trim colors, plus the raceway color matched to the fascia.
  • A section through the mount showing fasteners, penetrations, and concealed wiring.
  • A note that electrical components are listed and that the listing mark is not visible to customers.
  • Service access for the transformer or driver and a local disconnect.
  • Weight, and a structural note if the facade cannot take the load without engineering.

UL 48 is the safety standard for electric signs, and UL 879 covers sign components. The National Electrical Code, NFPA 70, Article 600, is what inspectors use for electric signs. You do not need to recite those numbers to the landlord. You do need the drawing to show listed components, hidden wiring, no light leaks, and a way to service the sign. Sample criteria often require exactly that, including PK housings or another approved insulating sleeve at fascia penetrations.

If the load is high for the facade, a licensed structural engineer has to review it. On our projects that engineering sits with the same team that prepares the permit drawings, through our Charlotte fabrication shop and Carolina Commercial Electric for the electrical work. The tenant should not be coordinating a separate electrician who has not seen the raceway detail.

Who approves the sign, and in what order?

Three yeses are common, and they are not interchangeable.

  1. Landlord, in writing. Verbal approval from a property manager does not hold. Unapproved signs can be ordered changed at the tenant's cost.
  2. City sign permit. Use the landlord-approved drawings. Do not apply with an earlier version.
  3. Install release. The landlord often wants the permit copy and the installer's insurance before anyone is on the fascia. Many criteria also require the landlord to approve the sign vendor.

The tenant pays for permits, fabrication, and installation unless the lease says otherwise. Plan the calendar around review, not around a logo meeting. A clean packet moves. A packet missing the elevation or the size comparison sits in a queue.

Carolina Signs and Wonders submits drawings and city packages as part of the project, then installs with our own crews. We work across the Carolinas, including Charlotte, Raleigh, Greensboro, Wilmington, Columbia, Greenville, and Charleston. Hours for a first conversation are Monday through Friday, 9:00 a.m. to 4:30 p.m. Eastern.

For the property-wide document itself, use the tenant signage criteria package guide. That page is for the developer writing the standard. This one is for the occupant who has to satisfy it. Broader retail programs live on the retail store signs guide, and a single-business identity that is not tied to a landlord band belongs with business signs.

Request a quote for your tenant sign submittal

Frequently Asked Questions

What is a tenant sign?

A tenant sign is the storefront identification a landlord allows one occupant to place on a multi-tenant property. It is usually channel letters or a cabinet on that tenant's sign band. It is not a tenant parking sign, and it is not the shared pylon for the whole center.

Can a tenant install a sign without landlord approval?

No. Lease criteria typically require written landlord approval of shop drawings before permit and installation. A sign installed early can be ordered removed or rebuilt to the criteria, at the tenant's cost.

How big can tenant signs be?

Size comes from the criteria and the city, and the stricter rule wins. Many shopping-center criteria cap the sign at 75 percent of the sign band and about 2 square feet of sign face per linear foot of that tenant's frontage. Measure the band before you lock letter height.

Do tenant signs need a permit?

Illuminated wall signs almost always need a local sign permit, and often an electrical permit. Submit the drawings the landlord already approved. Send the landlord a copy of the permit before installation if the criteria requires it.

Who builds and installs the sign?

The tenant hires the sign company unless the lease names one. The landlord may have to approve the vendor and insurance. Carolina Signs and Wonders can prepare the submittal, fabricate the sign in Charlotte, and install it under one scope.

What should you send for a consultation?

Send the lease sign exhibit, a straight-on photo of the storefront, the frontage width if you have it, and the logo file. Note whether a pylon panel is also in the lease. With those pieces, we can tell you whether the current logo fits the band or needs to be redrawn before anyone fabricates it.

There is no fixed price. Every facade, jurisdiction, and criteria set changes the scope, so the quote follows a short consultation rather than a rate card.

Get a free quote

Let's Bring Your Vision to Life

Contact us today for a free consultation on your next signage project.